When the connection is made directly with the electricity supply:
- Make sure that there is a device to disconnect the appliance from the mains with a contact opening
distance sufficient for complete disconnection in category III overvoltage conditions.
- Place a single-pole switch between the appliance and the electricity supply. The switch must be of a
suitable charge for the appliance with a minimum opening between the contacts of 3 mm.
- Remember that the earth wire must not be interrupted by the switch.
- Alternatively the electrical connection can also be protected by a differential switch of high sensitivity.
- You are strongly advised to fix the special yellow-green earth wire to an efficient earthing system
Room ventilation – Location and venting.
ATTENTION: An exhaust fan may be used with the appliance; in each case it shall be installed in
conformity with the national standards in force.
ATTENTION: Exhaust hood operation may affect other vented appliances; in each case it shall be
installed in conformity with the national standards in force.
- CHANGING THE NOZZLES FOR USE WITH OTHER TYPES OF GAS:
To change the nozzles of the burners use the following procedure:
Lift up the burners and unscrew the nozzles ( Fig. 9) using an adjustable spanner of 7 mm and change the
nozzles with those designed for the new gas supply according to the information given in TABLE A shown
below.
TABLE N°2: Adaption to various types of gas
Burner Types of Gas Pressure Nozzle
Diameter
Hourly Gas
Consumption
kPa mm. (MJ)
Semi-Rapid NG 1.0 1,17 6,6
Propane 2.75 0,73 6,9
Rapid NG 1.0 1,50 11.0
Propane 2.75 0,92 10.8
Dual NG 1.0 0,80 3.1
Inner Propane 2.75 0,50 3.1
Dual NG 1.0 2x1,14 12.5
Outer Propane 2.75 2x0,73 13.9
CAUTION: save the orifices removed from the appliance for future use
Regulation of burners
Regulation of the "MINIMUM" on the burners
To regulate the minimum on the burners carry out the following procedure indicated below:
1) Turn on the burner and put the knob onto position MINIMUM ( small flame ).
2) Remove the knob ( Fig. 10) of the tap which is set for standard pressure. The knob is found on the bar of
the tap itself.
3) Beside the tap bar on the work top, use a small screwdriver that fits the screw (gold) found on the lower
part of the tap and turn the fixing screw to the right or left until the flame of the burner is regulated in the most
suitable way to MINIMUM.
4) Make sure that that the flame does not go out when changing the position quickly from MAXIMUM to the
MINIMUM position.
ATTENTION: The regulation described above can be carried out only with burners using natural gas,
while with burners using propane gas the screw must be fully screwed in, in a clockwise direction.
Descriptions
DESCRIPTIVE CAPTION FOR HOB (fig.11)
1. Dual burner
2 Griddle
3. Rapid burner
4. Medium burner
5. Dual out burner control knob
6. Dual in burner control knob
7. Rear element griddle control knob
8. Front element griddle control knob
9. Rapid burner control knob
10. Medium burner control knob