A label on the last page of this manual and on the lower part of the case indicates the conditions for
regulating the appliance: type of gas and pressure used.
IMPORTANT: This appliance must be installed in accordance with the norms in force of the country
concerned and it must only be used in a well-ventilated place.
ATTENTION: Remember that the gas inlet connection for the appliance is threaded 1/2 gas cylindrical
male in accordance with the norms UNI-ISO 228-1. (Fig. 6-7)
There are two ways to make the connection to the main gas line:
A. The hotplate can be connected with rigid pipe as specified in AS5601 table 3.1.
B. The hotplate can be connected with a Flexible Hose, which complies with AS/NZS 1869 (AGA Approved),
10mm ID, class B or D, no more than 1.2m long and in accordance with AS5601.
WARNING: Ensure that the hose assembly is restrained from accidental contact with the flue or flue outlet of
an underbench oven and it does not contact the hot surfaces of the hotplate, oven, dishwasher or other
separate appliance that may be installed underneath or next to the hotplate. The hose should not be
subjected to abrasion, kinking or permanent deformation and should be able to be inspected along its entire
length. Unions compatible with the hose fittings must be used and connections tested for gas leaks.
The supply connection point must be accessible with the appliance installed. Fit the supplied elbow and
gasket as shown in Fig.20. The gas inlet connection has a 1/2" BSP male thread. When making the
connection, take care not to apply excessive stress by counterbalancing tightening force. Ensure that the
available gas supply is the same as the gas type label affixed to the base of the hob. If not, contact
Bertazzoni for a Gas Conversion Kit. The gas supply pressure must be adjusted in accordance with the data
label for the gas type.
Natural Gas
The natural gas regulator supplied must be fitted for natural gas. Ensure the arrow on the regulator points
towards the direction of the gas flow. The test point pressure must be adjusted to 1.00 kPa with the largest
burner operating on maximum flame.
Propane Gas
Fit the Propane Gas test point assembly (supplied in the gas conversion kit). An AGA Approved gas
regulator suitable for a supply pressure of 2.75kPa should be part of the gas tank supply.
Electrical connection
Connection to the electricity supply must be carried out according to the norms and indications of
the law in force.
Before carrying out the connection check that:
- The electric charge of the system and the sockets are suitable for the maximum power of the appliance
(see label on the lower part of the case).
- The socket or system is equipped with an efficient earth connection according to the norms and indications
of the law currently in force. No responsibility can be held if these indications are not respected.
When the connection to the electricity supply is made with a socket.
Fit onto the electric cable a standard plug ( if it is not provided ) which is appropriate for the charge indicated
on the label. Connect up the wires according to the diagram in Fig. 10 taking care to respect the
corresponding pairs listed below:
letter L (phase) = brown coloured wire;
letter N (neutral) = blue coloured wire;
symbol”
” earth = green-yellow coloured wire;
- The electric cable must be positioned so that it cannot reach a temperature of over 75 K at any point.
- Do not use reducers, adapters or shunts for the connection as they could cause false contacts and
subsequent dangerous overheating.
WARNING: The plug must be made accessible after installation for easy servicing and maintenance.
WARNING: If the supply cord is damaged, it must be replaced by the manufacturer or its service agent or a
similarly qualified person in order to avoid a hazard.